Conventional Compensation Systems

EVA Europe

EVA EUROPE / EQUIPMENT SOLUTIONS

Conventional Compensation

Contactor-switched capacitor stages for suitable load conditions. Suitability must be checked against harmonics and operating duty; a conventional bank is not a universal solution for distorted networks.

Conventional Compensation
Reference product image. Equipment and ratings are confirmed for the selected project design.

TECHNICAL DETAILS

Define the Right Configuration.

Staged compensation

Define total kvar and stage sizes against the load profile. Switching devices and the controller are confirmed for the selected panel.

Network suitability

Check harmonic conditions and existing capacitors before selecting a conventional bank. A reinforced capacitor alone does not establish harmonic-filter performance.

Panel integration

Specify protection, discharge provisions, ventilation and service access. Do not assume all options in an old catalogue apply to the quoted configuration.

Reference Technical Data

Values are retained from the existing product reference and are not universal limits for every supplier. Confirm the ratings and applicable configuration in the approved datasheet.

Nominal Voltage400V AC
Frequency50 Hz
Response Time10sec-60sec
Switching MethodCompensation Contacts

TECHNICAL SELECTION

What to Include in Your Enquiry.

Load measurements

System voltage, active / reactive power profiles, existing power factor and measured harmonics.

Control & stages

Required kvar, stage sizes, switching frequency, response time, measurement point and CT arrangement.

Panel integration

Existing panels and capacitors, ventilation, protection, available space and maintenance access.

Send a single-line diagram, technical specification or written requirements. Missing parameters are clarified before the final technical offer.

QUALITY & SUPPLY SCOPE

Match the Documents to the Equipment.

Technical Documents

The agreed package may include datasheets, general arrangements, electrical diagrams, component schedules and installation / operating instructions. Required tests, verification records and applicable declarations are specified for the selected design.

Clear Supply Boundaries

The quotation identifies the equipment, accessories, interfaces, transport and included services. Installation, cable connections and commissioning are included only when expressly agreed.

COMMON QUESTIONS

Before You Order.

Are the reference images and ratings the final specification?

They illustrate a product family or reference design. Manufacturer, ratings, dimensions, accessories and documents are identified in the agreed technical offer.

How do I obtain a price and delivery schedule?

Send the equipment type and quantity, key parameters, project location and required date. Attach the available drawings or specification to your email.

ENQUIRE WITH EVA EUROPE

Let’s Define Your Equipment Package.

System voltage, active / reactive power profiles, existing power factor and measured harmonics.

Conventional Compensation Systems

eVAR-SC type conventional compensation panels are used where the harmonic pollution rate is above the limits and where the load changeover rate is slow. These panels are designed mainly to reduce system costs. These panels are manufactured with reactors as a standard, also, thyristors instead of contactors could be used. In addition, tube capacitors (cylindrical type) with 440V continuous operating voltage are used in these panels too.

eVAR brand thyristor module is used in eVAR-SC type compensation panels.

TypeeVAR-SC
Nominal Voltage400V AC
Continuous Operating Voltage440V / 525V AC
Overcurrent2xIn
Frequency50 Hz
Ambient Temperature-25°C – +55°C
Response Time10sec-60sec
Switching MethodCompensation Contacts
Protection Against HarmonicsPartially (reinforced type capacitor is used)
Metal-Sheet types and thicknessesStainless, electro galvanized (1,5mm – 2mm)
StandardsIEC-61439-1 and IEC-61439-2

Alarms:

  • Insufficient Compensation
  • Extreme Temperature
  • Capacitor Failure Report
  • Over / Under Voltage
  • Harmonic Pollution

Advantages:

 

  • Fast and accurate capacitor reporting
  • Normal or fast operating mode selection
  • Suitable for balanced or unbalanced loads
  • Three-phase, Two-phase and or single-phase stages according to the system requirement
  • Easy commissioning
  • Sufficient steps number according to the needs
  • Shunt reactor step